This question was closed without grading. Reason: Other
Jul 31, 2017 05:55
7 yrs ago
1 viewer *
English term
Sphere Location Diameter Error
English to Russian
Tech/Engineering
Other
Вспомогательное видео: https://www.youtube.com/watch?v=a2W6AKJ8Xps
PSize - Sphere Probing Size Error.
The operator measures a sphere with the probe.
The error is the difference between the measure and actual diameter of the sphere.
PForm - Sphere Probing Form Error.
The operator measures a sphere with the probe.
The error is maximum distance of any point from the best-fit sphere.
LDia - *Sphere Location Diameter Error*.
The operator measures a sphere with the probe from multiple orientations.
The error is the diameter of the spherical zone containing the centers of the measured spheres.
The operator measures two sphere, or two points, with the probe.
The error is the difference between the measure and actual length between the spheres or points.
LDia - Sphere Location Diameter Error.
The operator measures a sphere with the probe from multiple orientations.
The error is the diameter of the spherical zone containing the centers of the measured spheres.
Perform a Sphere to Sphere, or Point to Point length measurement in order to certify the volumetric accuracy (EUni) of the .
Ensure that you digitize points on the entire Sphere surface.
PSize - Sphere Probing Size Error.
The operator measures a sphere with the probe.
The error is the difference between the measure and actual diameter of the sphere.
PForm - Sphere Probing Form Error.
The operator measures a sphere with the probe.
The error is maximum distance of any point from the best-fit sphere.
LDia - *Sphere Location Diameter Error*.
The operator measures a sphere with the probe from multiple orientations.
The error is the diameter of the spherical zone containing the centers of the measured spheres.
The operator measures two sphere, or two points, with the probe.
The error is the difference between the measure and actual length between the spheres or points.
LDia - Sphere Location Diameter Error.
The operator measures a sphere with the probe from multiple orientations.
The error is the diameter of the spherical zone containing the centers of the measured spheres.
Perform a Sphere to Sphere, or Point to Point length measurement in order to certify the volumetric accuracy (EUni) of the .
Ensure that you digitize points on the entire Sphere surface.
Proposed translations
(Russian)
3 | диаметрическая ошибка местоположения сферы | Konstantin Chernoukhov |
Proposed translations
1 day 2 hrs
диаметрическая ошибка местоположения сферы
Согласно определению, ошибка определяется диаметром сферической зоны (заданной центрами сфер, полученных при измерении на данной сфере с разных направлений).
Поэтому эту ошибку можно назвать диаметрической. Термин "диаметрический" используется нечасто, но все же используется. Например, см. описание SOLIDWORKS: "Создание размеров данного типа полезно при создании эскизов для вращающейся геометрии, для которой требуется несколько диаметрических размеров."
Поэтому эту ошибку можно назвать диаметрической. Термин "диаметрический" используется нечасто, но все же используется. Например, см. описание SOLIDWORKS: "Создание размеров данного типа полезно при создании эскизов для вращающейся геометрии, для которой требуется несколько диаметрических размеров."