Spanish term or phrase:

piqueta de cobre

English translation:

copper ground rod

Added to glossary by Joan Chastain
Aug 10, 2003 19:53
21 yrs ago
1 viewer *
Spanish term

piqueta de cobre

Spanish to English Tech/Engineering Electronics / Elect Eng electricity
Conjunto de piquetas de cobre longitud 2 mts seccion 25 mm en numero
necesario para obtener una resistencia de tierra inferior a 80 Ohmios

Proposed translations

+1
41 mins
Selected

copper-clad ground rod / copper-coated ground rod

I think this may be it.

HTH

Sheila

copper-clad ground rod

[PDF]BETTER GROUNDING
Formato de archivo: PDF/Adobe Acrobat - Versión en HTML
... Grounding Electrode 9 62 270 3.7k 30k Copper-Clad Rod ... XIT (Ohms) 0.5 9 22 240 2k CCGR
Chem-Rod (Ohms) 0.2 2 10 90 1k Table 2. Cost Comparison of Ground Rods & ...
www.ees-group.co.uk/downloads/Better Grounding.pdf - Páginas similares

Ground Problems - [ Traduzca esta página ]
... eventually reaches the earth ground system, a ground rod, through a heavy gauge copper
wire 11 feet ... of equipment goes directly to the heavy ground strap that ...
www.radioworks.com/nbgnd.html - 44k - En caché - Páginas similares



The Path of Least Resistance - [ Traduzca esta página ]
... equipment installation instructions require a ground rod without an ... resistance paths,
including the one of least resistance. ... driving 10 ft of copper-clad steel ...
www.ecmweb.com/ar/electric_path_least_resistance/ - 48k - En caché - Páginas similares


Grounding a Metal building concerning ground rod.. - [ Traduzca esta página ]
... Russel, Tom Thanks again. I picked up a 5/8" x 12' copper coated rod. I have driven
many ground rods when I did CATV contracting work. Mostly 8 footers thou. ...
ths.gardenweb.com/forums/load/ wiring/msg072354034729.html - 12k - En caché - Páginas similares


--------------------------------------------------
Note added at 46 mins (2003-08-10 20:40:08 GMT)
--------------------------------------------------

Galvan Industries :: Misconceptions of Good Grounding Practices : ... - [ Traduzca esta página ]
... in northern MN you may expect 15 ohms resistance. However, that very same ground
rod during the freezing winter months may rise to 80 ohms, or significantly ...
www.galvanizersonline.com/electrical/commandments.html - 10k - En caché - Páginas similares

Ground Rods
The purpose of a ground rod is to connect the grounding system to earth where current may be dissipated in moist soil.  They should be at least 8 feet long, but a 10-foot rod is better.  A longer ground rod will reach a soil with a higher moisture content.  Moist soil carries current much better than drier soil.  Placing a ground rod in moist soil is particularly important considering the drought conditions of recent years.
 
Ground rods should be either copper-clad or galvanized steel rods having a minimum diameter of 5/8” with a 3/4” diameter preferred.  The larger the rod diameter, the lower it’s resistance to current flow.  The National Electric Code (NEC) mandates two ground rods unless you can show less than 25 ohms resistance with one rod.


http://www.rec.udel.edu/Poultry/VanWicklen/APEN-v1n1.htm
Peer comment(s):

neutral Daniel Mencher : I should hope you think this may be it. You entered it as an answer, didn't you? Just playing, I actually guess it may be. Luck! :)
7 mins
agree Nicholas Hogg : I would take out the coated. I found many hits with copper ground rod.
9 mins
Something went wrong...
4 KudoZ points awarded for this answer.
-1
3 mins

copper pickaxe

copper pickaxe

--------------------------------------------------
Note added at 2003-08-10 19:58:23 (GMT)
--------------------------------------------------

piqueta = pickaxe
de = of
cobre = copper

piqueta de cobre = pickaxe of copper = copper pickaxe

¡Buena suerte! / Good luck!

-Dan
Peer comment(s):

disagree Nicholas Hogg : I am curious to know just how this would fit into the rest of the sentence
42 mins
Well, you know what they say: Curiosity killed the cat.
Something went wrong...
-1
28 mins

Copper mattock/mason`s hammer/pick

Robb.
Peer comment(s):

disagree Nicholas Hogg : I am curious to know how this would fit into the rest of the sentence
18 mins
a set of copper mattocks../or a set of copper mason`s hammers/ or a set of copper picks.
Something went wrong...
Term search
  • All of ProZ.com
  • Term search
  • Jobs
  • Forums
  • Multiple search