English term

"Zero machine (set resolver offset)"

English to Spanish Tech/Engineering
4.3.5 ZERO MACHINE (SET RESOLVER OFFSET)

This selection is used to auto zero the resolver. To set the machine zero (resolver offset) perform the following:

1) Select "6: VERIFY CAN PRX1 LOCATION/TIMING" and observe the "ACTUAL ABSOLUTE POS:" field. Verify that as the machine is rotated forward (either jogged or barred) that the position increases linearly from 0 through 1079 for “Rotary Trip” machines or 0 through 719 for interposer trip machines. If not, swap the S1 and S3 leads of the resolver at the M4500 resolver connector. Then verify that the position then indeed does increase with forward movement. Press to exit back to the primary set-up menu.

2) Position the machine at machine zero (“A” trip cam follower just past “A” trip cam, see the electrical timing procedure drawing, figure 3).

3) Auto zero the resolver by selecting "5: ZERO MACHINE" from the primary set-up menu. Enter "0" to zero the resolver. The timing set-up menu will be displayed, now showing the "POS:" at zero.

4) The M4500 will calculate the actual offset value required to make this the 000 position and will display this number in the offset field.

4) Exit back to the primary set-up menu by pressing . Exit back to the default screen by pressing again.

Proposed translations

3 days 16 hrs
Selected

calibrar, poner a cero

se suelen utilizar indistintamente.
Aoto-zer se puede traducir como calibración automática o auto calibración
Something went wrong...
4 KudoZ points awarded for this answer. Comment: "Thank you :)"
11 mins

calibrar maquina

Auto Zero- Autocalibrar

--------------------------------------------------
Note added at 2001-12-19 23:20:20 (GMT)
--------------------------------------------------

set resolver offset- calibrar desplazamiento del resolvador
Something went wrong...
1 hr

blanquear

Autozero es una anglicismo que significa que la mediciOn se ha calibrado ante un 'blanco' o muestra referente (usualmente conteniendo aquella sustancia que contiene a la muestra problema). La mAquina asume el blanco como 'zero' y todo lo que detected por encima de este serA lo correspondiente a la muestra problema.
Something went wrong...
2 hrs

calibrador (o sistema de medición) [fija el transformador de coordenadas a cero]

This is what I understand from reading the paragraph.