Jun 5, 2020 01:58
4 yrs ago
25 viewers *
English term

aEEG monitoring

GBK English to Italian Medical Medical (general)
Amplitude-integrated EEG (aEEG) is an easily accessible technique to monitor the electrocortical activity in preterm and term infants in neonatal intensive care units (NICUs). This method was first used to monitor newborns after asphyxia, providing information about future neurological outcomes.
Example sentences:
In a study of 202 newborns, those who underwent aEEG monitoring had greater precision in the diagnosis of neonatal seizures than in contemporary controls with diagnosis by clinical signs alone. (ScienceDirect)
In the preterm group, mean time to initiate aEEG monitoring was 5.2 (±1.2) h of life, and pathological trace or DLVP were associated with higher rates of poor early outcome (p=0.03, PPV 90.9%, NPV 75%, RR=3.63). (Jornal de Pediatra)
However, there are several challenges that delay the translation of aEEG monitoring into clinical practice in preterm infants. A major obstacle when comparing results from different studies is due to the differences in study populations, evaluated time periods, aEEG parameters, outcome assessments, and statistical reporting (7,19,20,21). (nature)
Change log

Jun 5, 2020 01:30: changed "Kudoz queue" from "In queue" to "Public"

Jun 5, 2020 01:58: changed "Stage" from "Preparation" to "Submission"

Jun 8, 2020 09:54: changed "Stage" from "Submission" to "Completion"

Proposed translations

+4
3 hrs
Selected

Monitoraggio tramite Elettroencefalografia ad ampiezza integrata

Definition from Ospedale Bambin Gesù:
L'elettroencefalografia ad ampiezza integrata, permette di registrare l'attività elettrica cerebrale in continuo. Sono ormai numerosi gli esempi che ne dimostrano la validità. Il suo impiego nel monitoraggio continuo delle funzioni vitali permette di sorvegliare la funzione cerebrale nei pazienti che hanno una accertata patologia neurologica. Questa tecnica è molto utilizzata per l'identificazione delle crisi epilettiche e della risposta alla terapia. Il CFM è utile anche per la valutazione della maturazione dell'attività elettrica cerebrale ad esempio nei pazienti pretermine. L'aEEG è una semplificazione dell'elettroencefalografia tradizionale ma, a differenza di questa, ha il vantaggio di permettere un monitoraggio continuo, di essere di più semplice interpretazione e quindi di poter essere valutata dal personale medico-infermieristico della Neonatologia.
Example sentences:
Elettroencefalografia ad ampiezza integrata Il tracciato è derivato da un segnale EEG registrato da una coppia di elettrodi biparietali o da due canali (un canale per ogni emisfero) mediante 4 elettrodi. (SIPPS)
SCHEDA TECNICA MONITOR DELLA FUNZIONE CEREBRALE Sistema per elettroencefalografia ad ampiezza integrata (aEEG) con monitoraggio in continuo di: - almeno due canali di EEG per poter analizzare l’attività elettrocorticale di due emisferi cerebrali (sia in tempo reale sia memorizzati precedentemente - in “review”), - duecanalidiaEEGperognisingoloemisferoeuncanaleaEEGcrosscerebrale - impedenza di ogni singolo elettrodo. (Azienda sanitaria provinciale Agrigento)
Peer comment(s):

agree Rossella Zugan : yes
3 hrs
grazie
agree Silvana Cinus
3 hrs
grazie
agree EleoE
10 hrs
grazie
agree Fabiana Franco
1 day 1 min
grazie
Something went wrong...
4 KudoZ points awarded for this answer.
3 hrs

Elettroencefalogramma a integrazione di ampiezza

...solo un'alternativa
Definition from alma mater studiorum :
Valutazione del danno ipossico-ischemico cerebrale nel neonato a termine mediante spettroscopia di risonanza magnetica ed elettroencefalogramma ad integrazione di ampiezza dopo trattamento ipotermico: studio caso-controllo
Example sentences:
AAllmmaaMMaatteerrSSttuuddiioorruumm––UUnniivveerrssiittààddiiBBoollooggnnaaDOTTORATO DI RICERCA MEDICINA MATERNO-INFANTILE E DELL’ETA’ EVOLUTIVA Ciclo XXI Settore scientifico disciplinari di afferenza: PEDIATRIA GENERALE E SPECIALISTICA MED/38 VALUTAZIONE DEL DANNO IPOSSICO-ISCHEMICO CEREBRALE NEL NEONATO A TERMINE MEDIANTE SPETTROSCOPIA DI RISONANZA MAGNETICA ED ELETTROENCEFALOGRAMMA AD INTEGRAZIONE DI AMPIEZZA DOPO TRATTAMENTO IPOTERMICO: STUDIO CASO-CONTROLLO (tesi di laurea)
Something went wrong...
3 hrs

monitoraggio aEEG

monitoraggio aEEG
- con elettroencefalografia ad ampiezza integrata (aEEG)
- con elettroencefalogramma ad integrazione di ampiezza (aEEG)
Definition from own experience or research:
monitoraggio con elettroencefalogramma ad integrazione di ampiezza (aEEG) <br /><br />I neonati che presentano un quadro clinico di encefalopatia ipossico-ischemica e/o positività dei parametri diagnostici di asfissia intrapartum devono essere sollecitamente sottoposti a * monitoraggio con elettroencefalogramma ad integrazione di ampiezza (aEEG) *, in relazione al quale si possono distinguere 4 tipi di tracciati:<br />- attività elettrica normale: tracciato con limite inferiore al di sopra dei 5 mcv e limite superiore al di sopra dei 10 mcv;<br />- attività elettrica moderatamente patologica: tracciato con limite inferiore al di sotto dei 5 mcv e limite superiore al di sopra dei 10 mcv;<br />- attività elettrica severatamente patologica: tracciato con limite inferiore al di sotto dei 5 mcv e limite superiore al di sotto dei 10 mcv;<br />- convulsioni: tracciato con &quot;denti di sega&quot;<br /><br />Fonte<br />Pediatria generale e specialistica<br /><b><a href="https://books.google.it/books?id=BIvnDwAAQBAJ&pg=PA33&lpg=PA33&dq=monitoraggio+aeeg+ampiezza&source=bl&ots=HdhlnZ5E_X&sig=ACfU3U2jKHiWe7uaR-MRn7p-m6AuSP0Gqg&hl=de&sa=X&ved=2ahUKEwjsuc798-npAhXl0aYKHUD7DPAQ6AEwCXoECAoQAQ#v=onepage&q=monitoraggio%20aeeg%20ampiezza&f=false" rel="nofollow noopener" target="_blank">https://books.google.it/books?id=BIvnDwAAQBAJ&pg=PA33&lpg=PA...</a></b>
Example sentences:
Sistema totalmente integrato per elettroencefalografia ad ampiezza integrata (aEEG) destinata al monitoraggio cerebro-funzionale a lungo termine, specifico per i neonati nella terapia intensiva neonatale, eseguibile anche da personale non altamente qualificato. Caratteristiche tecniche: Acquisizione segnali realizzata utilizzando fino a tre canali differenziali (uno per ogni singolo emisfero e un cross-cerebrale bi-parietale); Ampio display a colori (15’’) touch screen (Azienda sanitaria locale (AUSL) )
Something went wrong...
Term search
  • All of ProZ.com
  • Term search
  • Jobs
  • Forums
  • Multiple search