Nov 18, 2008 17:18
15 yrs ago
4 viewers *
English term

Once Through Cooling

English to Italian Tech/Engineering Mechanics / Mech Engineering
Once Through Cooling
Receives water from a river, bay, lake, or ocean for one pass through heat exchangers where heat is removed from the system and transferred back to the river, bay, lake or ocean.

Su archivionucleare.com ho trovato il seguente testo:

As methods for the cooling of the plant condenser, a choice exists between the practically total dissipation of the heat into particularly receptive water bodies (once through cooling), and dissipation largely into the atmosphere (wet towers).

Le wet towers sono le torri di raffreddamento a umido (o per evaporazione.

Ho trovato once through spesso lasciato non tradotto. TIA!
Proposed translations (Italian)
5 +4 raffreddamento a ciclo aperto

Discussion

Andreina Baiano (asker) Nov 18, 2008:
Potrebbe essere raffreddamento a ciclo aperto

http://www.gabrieleascione.it/prospetti/cloriti DS-605-IT-R0...
raffreddamento a ciclo aperto (once through); nell’itticoltura e nella
molluschicoltura. Vantaggi. • Celle robuste e compatte ...

SATEMA
Sistemi di raffreddamento a ciclo aperto (once through) e a ciclo chiuso. -
Piscine con acqua di mare, piscine termali, ospedali, cartiere, ecc. ...
http://www.satema.it/admin/uploads/3_030.pdf

Proposed translations

+4
22 mins
Selected

raffreddamento a ciclo aperto

ovvero l'acqua di raffreddamento passa solo una volta attraverso lo scambiatore e poi essa si raffredda con scambio termico con l'aria


PDF] FACT SHEET AND OVERVIEW REGULATING COOLING WATER USE AT EXISTING ... - [ Traduci questa pagina ]Formato file: PDF/Adobe Acrobat - Versione HTML
In a once-through cooling system, water is withdrawn directly from the source ... Because once-through cooling systems do not re-circulate the ...
www.catf.us/press_room/cwis_backgrounder.pdf - Pagine simili - Salva risultato

--------------------------------------------------
Note added at 25 min (2008-11-18 17:43:47 GMT)
--------------------------------------------------

In a once-through cooling system, water is withdrawn directly from the source waterbody, diverted through a condenser where it absorbs heat from the boiler steam, and then discharged back into the source waterbody at elevated temperatures. Because once-through cooling systems do not re-circulate the cooling water, they can require as much as a billion gallons of water per day.
Once-through cooling is used roughly 52% of power plants in the United States.
Peer comment(s):

agree Daniela Rita Mazzella
14 mins
agree Maria Luisa Dell'Orto
15 mins
agree Rossella Mainardis
3 hrs
agree Francesca Siotto
4 hrs
Something went wrong...
2 KudoZ points awarded for this answer. Comment: "Grazie per aver confermato (vedi nota aggiunta due minuti dopo la richiesta). Grazie a tutti."