French term
coffret de chantier
French to English
Tech/Engineering
Construction / Civil Engineering
health and safety
En cas d’utilisation d’appareils électriques portatifs, l’entreprise de sous-traitance disposera d’un coffret ou d’une station de chantier, munie d’un disjoncteur différentiel 30 mA, pour la protection des personnes et des matériels
Proposed translations
(English)
Change log
Feb 10, 2012 23:17: Tony M Created KOG entry
Proposed translations
+1
16 mins
Selected
(building) site connecting box
These are the sort of things you see stuck on a post around building sites, there are now quite strict regulations as to just what they must include.
--------------------------------------------------
Note added at 1 heure (2011-10-12 16:18:28 GMT)
--------------------------------------------------
Note that current building sitre regulations limit the length of extension leads, as pointed out by Bourth below, and hence most specifications state that a sufficient number of these 'coffrets' must be installed so that not working position is more than X metres from one; on one very extensive building site I translated the H&S requirements for (a large power station), this meant that there were dozens of these darned things to be installed, no doubt at great expense!
--------------------------------------------------
Note added at 1 heure (2011-10-12 16:18:28 GMT)
--------------------------------------------------
Note that current building sitre regulations limit the length of extension leads, as pointed out by Bourth below, and hence most specifications state that a sufficient number of these 'coffrets' must be installed so that not working position is more than X metres from one; on one very extensive building site I translated the H&S requirements for (a large power station), this meant that there were dozens of these darned things to be installed, no doubt at great expense!
Peer comment(s):
agree |
Bourth (X)
: Though might it not be a mobile unit, like a transformer? If there's only one of these things and the site is large, there'd be some long extension cords about!
14 mins
|
Thanks, Alex! No, I believe the 'coffret' is the base unit from which the other things are connected, and into which the trafos are plugged.
|
4 KudoZ points awarded for this answer.
13 mins
worksite control panel
I think this is what they mean
18 mins
site connection cabinet
electrical supply point.
57 mins
[Building] site power distribution unit
often seen as PDU
2 hrs
temporary fuse box during building work
Ours is still here after 6 years
It does carry out the function of debranching wjhen there is an overload
therefore it must be a fuse box?
--------------------------------------------------
Note added at 2 hrs (2011-10-12 16:58:42 GMT)
--------------------------------------------------
Yes ours is 30 mega amps as well
It does carry out the function of debranching wjhen there is an overload
therefore it must be a fuse box?
--------------------------------------------------
Note added at 2 hrs (2011-10-12 16:58:42 GMT)
--------------------------------------------------
Yes ours is 30 mega amps as well