Glossary entry (derived from question below)
English term or phrase:
SO2 span
Romanian translation:
gaz etalon/de calibrare SO2
English term
SO2 span
Multumesc anticipat pentru ajutor!!
4 +3 | (gaz de) span SO2 |
Claudia Coja
![]() |
4 | concentratia cunoscuta de SO2 |
Dora Ilie (X)
![]() |
SO2 span |
cristina48
![]() |
Dec 13, 2009 20:22: cristina48 changed "Field (specific)" from "Mechanics / Mech Engineering" to "Environment & Ecology"
Dec 15, 2009 06:49: Claudia Coja changed "Edited KOG entry" from "<a href="/profile/641998">Ana-Maria Badea's</a> old entry - "SO2 span"" to ""gaz etalon/de calibrare SO2""
Proposed translations
(gaz de) span SO2
vad ca si in RO e pastrat "span"
"Răspunsul la trecerea ***gazului span*** prin filtru.."
http://209.85.129.132/search?q=cache:zjUSuHPYNTAJ:www.anpm.r...
"gaz de span" http://www.mecrosystem.ro/produs/sistem-de-analiza-si-monito...
--------------------------------------------------
Note added at 1 day29 mins (2009-12-14 18:54:46 GMT)
--------------------------------------------------
In consens total cu Cristina, pentru ca si eu prefer sa traduc termenul atunci cand este posibil si sa-l preiau doar cand sunt in imposibilitate de a-i oferi un echivalent in limba romana, am mai cautat variante si am ajuns la concluzia ca si ***gaz etalon*** poate fi varianta corecta
"posibilitate de calibrare fara gaz etalon ..." http://caz.mecen.pub.ro/afriso.pdf
si in franceza suna similar " SO2 (Dioxyde de Soufre) - Bouteille gaz étalon à 5.0 ppm "http://www.accessoiresgaz.com/bouteille-gaz-etalon/bouteille...
agree |
Sandra Roselee
1 hr
|
multumesc :)
|
|
agree |
Iosif JUHASZ
12 hrs
|
Multumesc :)
|
|
agree |
cristina48
: M-am mai documentat şi se pare că asta e!
20 hrs
|
multumesc, Cristina :)
|
concentratia cunoscuta de SO2
Part of the QAQC process for many of the continuous analyzers is the daily zero/span cycle. Each day, usually in the early hours of the morning, the normal sample port is closed to the analyzer and, for about twenty minutes, zero air is fed to the analyzer. Zero air is air from a cylinder or air that has been filtered so that it contains almost no pollutant. The analyzer should read zero. If the analyzer does not read zero, then the data is adjusted by a corresponding amount.
This common procedure is known as baseline correction. After the zero air comes the span gas. Span gas is air with a known high concentration of pollutant. The analyzer should output a reading that is within ten percent of the known concentration. If it does not, then the analyzer must be calibrated. After the zero and span gases have been passed through the analyzer, the sample port is again opened. About ten minutes is allowed for the analyzer to recover before readings are accepted again as real.
http://wbea.org/content/view/24/63/#zero
Span-Gas - A gas of known concentration that is used routinely to calibrate the output level of an analyzer. See “Calibration Check Standard”.
http://www.env.gov.bc.ca/wsd/data_searches/field_sampling_ma...
Suppression ratio: The ratio of the lower-range value to the span. If range is 20-100 and therefore span is 80 and LRV is 20, the suppression ratio is 20/80 = 0.25 or 25%.
http://www.omega.com/literature/transactions/volume3/glossar...
In realitate, insa, pentru etalonarea analizoarelor se folosesc butelii etalon cu o concentratie cunoscuta de gaz. Pentru gazele de ardere, amestecurile de gaze etalon cele mai bune au o eroare relativa a concentratiei etalon de gaz de 1%.
http://www.emisii.ro/Erori monitorizare emisii, recomandari....
Reference comments
SO2 span
Argumente:
1) Vezi http://www.proz.com/kudoz/english_to_romanian/mechanics_mech...
2) Range of interval
Range
The range of the interval [a; b] is the difference b - a and is denoted by r[a; b].
NOTE The term “span” is sometimes used for this concept. (pag. 12)
3) Masurare SO2
Domeniu de m`sur`: 0..2000 ppm
Rezolutie: 1 ppm
Precizie: ±10 ppm (<150 ppm)
±5 % dvm (Δ150 ppm)
http://www.afriso.ro/multilyzer.html
Personal, aş opta pt. "interval/domeniu de măsurare SO2".
--------------------------------------------------
Note added at 23 ore (2009-12-14 17:30:10 GMT)
--------------------------------------------------
http://www.afriso.ro/multilyzer.html
--------------------------------------------------
Note added at 23 ore (2009-12-14 17:30:43 GMT)
--------------------------------------------------
http://www.afriso.ro/multilyzer.html
--------------------------------------------------
Note added at 23 ore (2009-12-14 17:31:16 GMT)
--------------------------------------------------
Nu pot posta linkurile:(
--------------------------------------------------
Note added at 23 ore (2009-12-14 17:35:02 GMT)
--------------------------------------------------
http://www.bipm.org/utils/common/documents/jcgm/JCGM_200_200...
si
http://www.afriso.ro/multilyzer.html
--------------------------------------------------
Note added at 23 ore (2009-12-14 18:14:53 GMT)
--------------------------------------------------
Sper ca acum să pot posta:
http://www.bipm.org/utils/common/documents/jcgm/JCGM_200_200...
şi
http://www.afriso.ro/multilyzer.html
Draga Cristina, nu cred ca se supara nimeni, orice parere este pretioasa si ajuta mult la stabilirea celei mai bune variante finale ;) |
Discussion
si in franceza suna similar " SO2 (Dioxyde de Soufre) - Bouteille gaz étalon à 5.0 ppm "http://www.accessoiresgaz.com/bouteille-gaz-etalon/bouteille...
http://www.afriso.ro/multilyzer.html
http://www.bipm.org/utils/common/documents/jcgm/JCGM_200_200...