English term

tamper

English to Italian Medical Medical: Instruments PUNCTURE CLOSURE APPARATUSES AND SEALING PLUGS
the sheath houses a tamper for advancing the slideable collar along the placement rod toward the coupling feature and toward the anchor. The tamper may be driven manually or with an automatic driving system to force the slideable collar toward the anchor

The terms "tamp" or "tamping," as used herein, mean pushing or packing by one or a succession of pushes, blows, or taps

Discussion

Valentina LG Dec 14, 2016:
<0054> More particularly, turning to FIG. 13 (...) Similar to the above-described operation of a conventional puncture closure device 100, the sheath 216 houses a tamper 217 for advancing the slideable collar 280 along the placement rod 202 toward the coupling feature 226 and toward the anchor 208. Tamper 217 may be driven manually (i.e., by hand) or with an automatic driving system to force slideable collar 280 toward the anchor 208.

Inoltre:
<0035>The terms “tamp” or “tamping,” as used herein, mean pushing or packing by one or a succession of pushes, blows, or taps.

Un oggetto che svolge una funzione di questo tipo secondo me è uno stantuffo, anche se ovviamente è uno stantuffo più complesso di quello di una siringa (se no non ci vorrebbe un brevetto di venti pagine per descriverlo). Un'altra possibilità è chiamarlo in un modo più generico ("azionatore" o qualcosa del genere), ma come "involucro isolante" proprio non lo vedo.
Valentina LG Dec 14, 2016:
fbbest Fai benissimo a insistere se non ti torna. Ho guardato di nuovo i disegni e la descrizione e continuo a pensare che sia uno stantuffo (cavo, ma sempre stantuffo). Fai riferimento alle figg. 5 e 13:
<0049-0050> Referring again to FIG. 5 (...)
Further, placement rod 202 may extend from the first end 206 of the puncture closure device 200 to the anchor support 210 through a tamper 217 and through a sheath 216. Tamper 217 is also positioned within sheath 216 and abuts slideable collar 280. Tamper 217 has an outer diameter that is larger than an inner diameter of the slideable collar 280 (or an inner diameter that is smaller than an outer diameter of the slideable collar 280) so that an operator may apply a force to the tamper 217 and advance the compression element 280 along the placement rod 202 and/or the anchor support 210 in the direction of the second end 224 of the plug assembly 204.


Il tamper 217 è contenuto all'interno della guaina 216. Ha dimensioni tali che, azionando il tamper, si spinge 280 in avanti. 280 a sua volta scorre su 202.
(segue)
Inter-Tra Dec 14, 2016:
Perdonate, se insisto. Valentina indipendentemente dal punteggio, devi guardare bene i disegni, lo stantuffo è un pistoncino INTERNO che spostato avanti e indietro inietta o aspira. in questo caso è l'involucro INTORNO allo stantuffo. I disegni sono molto chiari.

Proposed translations

1 hr
Selected

stantuffo

Forse, in questo caso particolare e vista la funzione che svolge, lo puoi tradurre con "stantuffo" o "pistone".
Something went wrong...
4 KudoZ points awarded for this answer. Comment: "Grazie mille, penso sia corretto così"
18 hrs

involucro isolante/(filtro) antidissipativo

From the drawing(s) (tamper 217) it is a mass of material located around the core (for delaying any kind of escape)
as it were 'sigillato' and actually 'tampering' means 'manomettere'

--------------------------------------------------
Note added at 18 hrs (2016-12-13 06:22:20 GMT)
--------------------------------------------------

"Further, placement rod 202 may extend from the first end 206 of the puncture closure device 200 to the anchor support 210 through a tamper 217 and through a sheath 216. Tamper 217 is also positioned within sheath 216 and abuts slideable collar 280. Tamper 217 has an outer diameter that is larger than an inner diameter of the slideable collar 280 (or an inner diameter that is smaller than an outer diameter of the slideable collar 280) so that an operator may apply a force to the tamper 217 and advance the compression element 280 along the placement rod 202 and/or the anchor support 210 in the direction of the second end 224 of the plug assembly 204"
https://www.google.com/patents/US20070276433
Something went wrong...